UPV Digital RepositoryUPV-DRUniversity of the Philippines Visayas
 

Undergraduate Theses

Permanent URI for this collectionhttps://hdl.handle.net/20.500.14583/13

Browse

Search Results

Now showing 1 - 5 of 5
  • Thumbnail Image
    Item
    Determination of instrument detection limit and method detection limit of Varian 55B flame atomic absorption spectrometer for cadmium, chromium, copper, iron, lead, manganese and zinc using sips-10 and manual sample introduction methods
    Calawigan, Roland Joseph C. (Department of Chemistry, College of Arts and Sciences, University of the Philippines Visayas, 2009-04)
    Determination of detection limits is an essential measure of performance for a quantitative laboratory, method or analyst. In this study, the Instrument Detection Limit (IDL) and Method Detection Limit (MDL) of F-AAS Varian 55B for cadmium, chromium, copper, iron, lead, manganese and zinc were determined using the SIPS-10 and manual sample introduction methods. For IDL determinations, EPA’s SW-846 method (Test Methods for Evaluating Solid Waste and Physical/Chemical Methods) was employed for both sample introduction methods where deionized water was analyzed for twenty times for three non-consecutive days. MDL determinations were done based on the definition given by the United States Code of Federal Regulations (40 CFR part 136, Appendix B - Definition and Procedure for the Determination of the Method Detection Limit). In this procedure, MDLs were estimated by calculating the standard deviation from the analysis of a standard solution containing the analyte with a concentration determined from the estimated detection limit, which was also analyzed for twenty times. Results showed that for the determination of IDL, all of the elements have lower values (Cd 0.000887 mg/L, Cr 0.00435 mg/L, Cu 0.000128 mg/L, Fe 0.000816 mg/L, Pb 0.000742 mg/L, Mn 0.000985 mg/L, Zn 0.000585 mg/L) for the manual method than the SIPS-10 method (Cd 0.00399 mg/L, Cr 0.0150 mg/L, Cu 0.00222 mg/L, Fe 0.00913 mg/L, Pb 0.0217 mg/L, Mn 0.00132 mg/L, Zn 0.00445 mg/L). For MDL, the results showed variations for both the two sample introduction methods. The MDL values for cadmium, chromium, copper, iron, lead, manganese and zinc are 0.0374 mg/L, 0.0235 mg/L, 0.00203 mg/L, 0.0197 mg/L, 0.0805 mg/L, 0.00325 mg/L and 0.00686 mg/L in the manual method, respectively and 0.0101 mg/L, 0.0429 mg/L, 0.00280 mg/L, 0.0186 mg/L, 0.19 7 mg/L, 0.00312 mg/L and 0.0103 mg/L in the SIPS-10 method, respectively. Both methods have comparable precision for copper, iron, manganese and zinc determinations while SIPS-10 method is more precise for cadmium, chromium, and lead analysis.
  • Thumbnail Image
    Item
    Heavy metals (Cr, Cu, Pb, and Zn) concentrations of road-deposited sediments within six public plazas in Iloilo City
    Caceres, Rizza Daphet E. (Department of Chemistry, College of Arts and Sciences, University of the Philippines Visayas, 2011-04)
    Contamination from overland transportation is an unavoidable result of urbanization. Cr, Cu, Pb, and Zn arc common heavy metals introduced to the environment by transportation. Road-deposited sediment (RDS) samples were collected from six public plazas (Villa Plaza, Molo Plaza, Mandurriao Plaza, Plaza Libertad, Lapaz Plaza and Jaro Plaza) in Iloilo City from March 2010 to May 2010. 0.5M HC1 was used as extractant and heavy metals (Cr, Cu, Pb, and Zn) concentrations were determined using Flame Atomic Absorption Spectrophotometer (FAAS). The mean concentrations of Cr, Cu, Pb, and Zn in road-deposited sediments from six plazas were 8.79 ± 1.93, 40.90 ± 24.21, 60.74 ± 22.32, and 164.25 ± 25.0 mg/kg, respectively. Metal enrichment of Cr, Cu, Pb and Zn were approximately xl, x8, x7 and x18 more than the background values respectively. There was no significant temporal variation in metals concentrations of RDS between sampling collections. Generally, RDS from Plaza Libertad has the highest metal concentrations. Cu and Pb metals were highly correlated (R2 = 0.891) indicating possible similar sources. A good correlation (R2 = 0.918) was observed between Pb concentration and the number of vehicles that pass along the plaza per hour. Heavy metal concentrations in sediments from plazas have low hazard quotients but bioaccumulation of metals in the body could cause health effects. Efficiency of digestion procedures varied depending on characteristics, texture and composition of road-deposited sediments. 0.5M HC1 digestion was used because it is simple, cost-effective, time-efficient and it leaches out meaningful amounts of bioavailable metals. Using HC1 as extractant simulates human digestion since human stomach contains HC1 that could leach out metals if road-deposited sediments were ingested.
  • Thumbnail Image
    Item
    The adsorption capacity of silica gel and rice hull ash on phenol and aniline
    Bulatao, Ben Fermin P. (Department of Chemistry, College of Arts and Sciences, University of the Philippines Visayas, 2011-04)
    Chemical waste has been a problem here in the University of the Philippines Visayas, Miagao, Iloilo. Various methods of removal have been utilized. Extraction of silica gel from rice hull and rice hull ash was used to remove organic compounds (phenol and aniline). In this study, silica gel and rice hull ash adsorption on phenol and aniline were investigated with varying contact time and initial concentration. Silica gel reaches its optimum adsorption of both phenol and aniline at 60 minutes contact time. Silica gel was the basis for rice hull ash’s contact time because rice hull ash is 90% by weight silica gel.. Silica gel-phenol system decreases it adsorption capacity as the initial concentration is increased from 25 ppm to 100 ppm. Rice hull ash- phenol system, on the other hand, shows that the adsorption capacity increases as the initial concentration is increased. Both on silica gel-aniline system and rice hull ash- aniline system have increasing adsorption as initial concentration is increased. As the contact time is increased, adsorption increases only until it reaches its optimum adsorption which is 60 minutes contact time where saturation is reached. Increasing initial concentration however has different effect on adsorption on all system explained by the adsorption isotherms. The isotherms show that phenol has the fastest rate to form a monolayer (K and Q°) with the greatest binding strength (b) on silica gel. It is also observed that phenol and aniline formed a monolayer (1/n) on the surface of the silica gel and rice hull ash.
  • Thumbnail Image
    Item
    Anti-inflammatory and antibacterial activities of Batuan (Garcinia binucao) fruits
    Albano, Zella Faye (Department of Chemistry, College of Arts and Sciences, University of the Philippines Visayas, 2010)
    In this study, fresh fruits of batuan (Garcinia binucao) was evaluated for its antiinflammatory and antibacterial activities. The anti-inflammatory assay using Carrageenan-Induced Paw Edema Method showed that n-hexane extracts (65.79%) and dichloromethane extracts (64.91%) exhibited anti-inflammatory activities comparable to Indomethacin, the positive control (67.11%). The antibacterial assay using Paper Disk Diffusion Method showed that crude methanolic extracts, n-hexane extracts and dichloromethane extracts at 1000pg/mL were most effective against Staphylococcus aureus. The microbial indexes were 0.39, 0.47 and 0.50 respectively. The positive control, Amoxicillin has a 3.39 microbial index. The components of the three most active extracts (crude methanolic, n-hexane and DCM extracts) from both assays were separated through Thin Layer Chromatography and subjected to phytochemical tests. Crude methanolic extracts contained alkaloids, phenolic compounds and cardiac glycosides. Both n-hexane and DCM extracts contained terpenes, alkaloids, saponins, phenolic compounds and cardiac glycosides. These bioactive compounds present may have been responsible for the antiinflammatory and antibacterial activities of the extracts.
  • Thumbnail Image
    Item
    Partial purification of pH indicator extracted from Rhoeo spathacea
    Apa, Junna T. (Department of Chemistry, College of Arts and Sciences, University of the Philippines Visayas, 2009-04)
    pH test papers are still utilized nowadays despite the prevalence of pH meters, because it is more convenient to use in measuring the pH of a certain substance. The use of natural dye as a pH indicator can serve as a good substitute for an expensive commercial dye that most high schools cannot afford. The pH test papers were prepared by impregnation of 0.03% pure dye extracted from Rhoeo spathacea. TLC was performed to partially remove other plant dye components from the pH active ingredient. The color transition chart was then created at pH ranging from 1.0-13.0 at one unit interval using phosphate buffer. The color transition chart of pure dye extract was compared to the color transition chart of crude dye extract at different pH. Paper impregnated with 0.03% partially purified indicator dye extracted from Rhoeo spathacea showed color transitions from pink to red violet at pH 1.0-3.0; red violet to lavender at pH 3.0-4.0; lavender to blue at pH 4.0-7.0; blue to blue green at pH 7.0-8.0; blue green to green at pH 8.0-11.0; green to yellow green at pH 11.0-12.0; and yellow green to yellow at pH 12.0-13.0. Results also showed that the purified dye extract is a better pH indicator in comparison with the crude dye extract. Spectrophotometric determination of pKa of the indicator was unsuccessful due to the strong overlapping of the UV-Vis spectrum of the acidic and basic forms of the plant dye extract. Titration results showed that the plant indicator can serve as a substitute for the methyl red and phenolphthalein indicators for strong acid-strong base and weak acid-strong base titration, but not for weak acid-weak base titration.